Home > Electrical Equipment & Supplies > Transformers > 0.1Hz Very Low Frequency VLF AC High Voltage Tester 30kV40kV50kV60kV80kV VLF Test Equipment

0.1Hz Very Low Frequency VLF AC High Voltage Tester 30kV40kV50kV60kV80kV VLF Test Equipment

Product Description

Payments:L/C, D/A, D/P, T/T, Western Union, MoneyGram, Paypal

Delivery:3 Working Days

Origin:Wuhan, China

Packing:Plywood Case

Inspection:-

Samples:Not Avaliable

VLF AC HIPOT TEST SET
EPVLF

General Information:
VLF stands for Very Low Frequency. VLF is generally considered to be 0.1 Hz and lower, its major application is for testing solid dielectric cable, transformers, motors, generators, switchgear and other electrical apparatus.

A VLF hipot is just an AC output tester but with an output frequency of 0.1 Hz or lower rather than 50/60Hz. Although the frequency is very low, it is still an alternating current with polarity reversals every half cycle. At 0.1 Hz output, rather than 60Hz, it takes 600 times less current and power to apply an AC voltage to a capacitive load, like a long cable.

Features:
Adapts microprocessor controlled, can realize voltage set-up/down, measuring and protecting automatically. Manual intervention is allowable even during the auto voltage boosting.
Portable, easy to move.
Large LCD can display waveform clearly, and test report can be printed. Built-in printer.
The data of current, voltage, and waveform can be sampled at HV side.
A high voltage output protective resistor is provided in the voltage boost body in the design and this eliminates the need of additional protective resistor connected outside.
Closed-loop negative feedback circuit is adopted. No capacity rising during outputting.
Over voltage and current protection: When the output is beyond the limitation, the control unit will shut itself down within 20ms.

Specifications:

  1. Peak voltage: 80kV
  2. Output frequency: 0.1Hz, 0.05Hz and 0.02 Hz (selectable)
  3. Fuse:20A
  4. Maximum load capacity:1.1μF at 0.1Hz, 2.2μF at 0.05Hz, 5.5μF at 0.02Hz
  5. Measurement accuracy:3%
  6. Voltage positive and negative peak error:≤3%
  7. Voltage waveform distortion: ≤5%.
  8. Working environment:Temperature: -10ºC-+40ºC, 85%RH.
  9. Indoor or outdoor,
  10. Weight:Control unit:4kg
  11. HV unit: 50kg
  12. Power supply:220V 50Hz
ModelRated voltageLoad capacityFuseWeight
EPVLF-30/1.130kV (peak)

0.1Hz ≤1.1µF

0.05Hz ≤2.2µF

0.02Hz ≤5.5µF

10A

Controller:4kg

Booster:25kg

EPVLF-40/1.140kV (peak)

0.1Hz ≤1.1µF

0.05Hz ≤2.2µF

0.02Hz ≤5.5µF

10A

Controller:4kg

Booster:40kg

EPVLF-50/1.150kV (peak)

0.1Hz ≤1.1µF

0.05Hz ≤2.2µF

0.02Hz ≤5.5µF

20A

Controller:4kg

Booster:45kg

EPVLF-60/1.160kV (peak)

0.1Hz ≤1.1µF

0.05Hz ≤2.2µF

0.02Hz ≤5.5µF

20A

Controller: 4 kg

Booster:50 kg

EPVLF-80/1.180kV (Peak)

0.1Hz ≤1.1µF

0.05Hz ≤2.2µF

0.02Hz ≤5.5µF

20A

Controller: 4 kg

Booster:50 kg


More details on VLF testing 30/40/50/60/70/80/90kV please contact EPHipot, we have professional tech team to design correctly designed products and systems.